DC Power Cable Size Calc Downloads & RevenueDC Power Cable Size Calc · App Store
Not in any tracked top chart right now.
Updated 11 Nov 2026 · rankings refresh through the day
DeveloperNitrio
CategoryUtilities
Price4.99 AUD
Released
Rating★ 5.0 (2)
Version1.2
Age rating4+
First seen by us
11 Oct 2026
Installs (est.)1k+ worldwide
DC Power Cable Size Calc update history & changes
Last change · 7 events since 17 Nov 2018Full timeline ↓📈Dropped out of every chart we track🆕First spotted by AppInsider🆕Its developer released another app: MemoPop +📦Version 1.2
Full timeline · 7 events
- 📈DC Power Cable Size Calc dropped out of every chart we trackLast seen 11 Oct
- 🆕DC Power Cable Size Calc first spotted by AppInsider#53 in Top Paid · Utilities · Australia
- 🆕DC Power Cable Size Calc: its developer released another app: MemoPop +
- 🆕DC Power Cable Size Calc: its developer released another app: Trackly +
- 🆕DC Power Cable Size Calc: its developer released another app: Voltage Divider Calc
- 📦DC Power Cable Size Calc version 1.2- Updated for the newest devices.
- Minor bugs fixed. - 🆕DC Power Cable Size Calc released on the App Store
Collected from the stores by AppInsider since we first spotted the app. Dates are when we saw each change.
Rating
5.0 ★
2 ratings
Measured
DC Power Cable Size Calc on the App Store
App details
App ID
1439670635
Publisher
Tan Chia Ling
On the store since
Nov 2018
7 years on the store
Minimum OS
iOS 12.0+
iPhone 5s and later
Devices
iPhone · iPad
Universal purchase
Content rating
4+
Languages
1
EN
Size
9 MB
Also listed in
Productivity
DC Power Cable Size Calc downloads
Worldwide, per day, and installs to date. The band is open; the exact number is free with an account.
How this is calculated
Apple publishes no download counts. App Store downloads come from chart positions and daily rating growth per country, calibrated on Google Play install counts; lifetime installs from ratings worldwide × installs per rating. Confidence is the chance the real number is within half to double ours.
Active users
All platforms, worldwide. Free with an account.
Stickiness (DAU / MAU)
how many monthly users open it on a given day
How this is calculated
Monthly users come from lifetime installs across every store, fitted on monthly active user figures companies publish; daily users = monthly × the typical daily/monthly ratio for the category. Confidence is the chance the real number is within half to double ours.
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| Not charting right now. | ||
Ratings
App Store, worldwide.
Rating
5.0 ★
2 ratings
Measured
Ratings
2
Measured
About DC Power Cable Size Calc
DC Power Cable Size Calculator are electrical calculator to find approximate wire gauge/size based on the length of the wire, the voltage and the current (in amps).
Features:
- Instant calculation
- Result are copy able to other app
- Formula are include as reference
- Support various unit for each input
Cable sizes are important for low voltage battery cables, wind turbines, solar panels and load cables.
Common reasons for low voltage (12v, 24v or 48v) system faults are voltage drops through incorrectly sized cables. It can be very dangerous If the cable is too small, as the cable will heat up and potentially cause a fire. On contrast an oversized cables might cause energy or money waste.
Formula:
VDI = (Amps x Distance)/(%Volt Drop x Voltage)
VDI - Voltage Drop Index (a reference number based on resistance of wire)
Distance - One way wiring distance in feet
%Volt Drop = acceptable voltage drop
Cable Size by cross-sectional area [Cooper]
mm² = VDI x 1.1
The voltage drop value will vary depending on your application. The standard 2% are use to ensure delivering full potential to any needed electrical source. And 5% or more voltage drop is more common in automotive applications.
Safety Guide:
- Cable sizes should only be used as a guideline and all figures should be checked against the manufacturers data sheet.
- Cables should be fused / current protected to their max rating or less.
Thanks for your support and do visit nitrio.com for more apps for your iOS devices.
Features:
- Instant calculation
- Result are copy able to other app
- Formula are include as reference
- Support various unit for each input
Cable sizes are important for low voltage battery cables, wind turbines, solar panels and load cables.
Common reasons for low voltage (12v, 24v or 48v) system faults are voltage drops through incorrectly sized cables. It can be very dangerous If the cable is too small, as the cable will heat up and potentially cause a fire. On contrast an oversized cables might cause energy or money waste.
Formula:
VDI = (Amps x Distance)/(%Volt Drop x Voltage)
VDI - Voltage Drop Index (a reference number based on resistance of wire)
Distance - One way wiring distance in feet
%Volt Drop = acceptable voltage drop
Cable Size by cross-sectional area [Cooper]
mm² = VDI x 1.1
The voltage drop value will vary depending on your application. The standard 2% are use to ensure delivering full potential to any needed electrical source. And 5% or more voltage drop is more common in automotive applications.
Safety Guide:
- Cable sizes should only be used as a guideline and all figures should be checked against the manufacturers data sheet.
- Cables should be fused / current protected to their max rating or less.
Thanks for your support and do visit nitrio.com for more apps for your iOS devices.
Latest updates
1.2
- Updated for the newest devices.
- Minor bugs fixed.