EchoLab Downloads & RevenueEchoLab · App Store
EchoLab is #81 in Medical Paid in Brazil and charting in 6 of 30 countries we track.
Updated 11 Nov 2026 · rankings refresh through the day
Full timeline · 20 events
- 📈EchoLab new best rank in the overall chart: #126Top Paid · All Apps · AR
- 📈EchoLab charting in a new countryArgentina
- 📈EchoLab new best rank in the overall chart: #136Top Paid · All Apps · CO
- 📈EchoLab charting in a new countryColombia
- 📈EchoLab entered the top 10Top Paid · Medical · BR
- 📦EchoLab updated to version 14.0.1EchoLab v14.0.1:
• Minor bug fixes and compatibility updates for iOS 27.
EchoLab v14.0:
• Analysis of prosthetic aortic, mitral, and pulmonic valves updated using the 2023 guidelines from the American Society of Echocardiography, the Society for Cardiovascular Magnetic Resonance, and the Society of Cardiovascular Computed Tomography.
• Option to designate surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) added to Quick Entry (aortic stenosis), Aortic Valve Area (VTI), and Aortic Valve Area (velocity) views. “TAVR baseline” button added to these views for entry of Doppler data obtained shortly after the TAVR procedure.
• Quick Entry (pulmonic stenosis) added as a new view for assessment of native and prosthetic pulmonic valves, with the option to designate a bioprosthetic pulmonic valve or a pulmonic valve homograft.
• Updates for compatibility with iOS 27.
EchoLab is optimized for Dark Mode, ideal for use in the dimmed lighting of a typical echocardiography reading room.
Remember that designating Quick Entry views as favorites permits easy access to the most frequently used echocardiographic measurements under the Favorites tab. Designating the Demographics and Clinical Conditions view as a favorite is a great way to direct the Analytic Engine from a central point.
Remember also to check out the bundled Apple Watch app for EchoLab, providing a ready reference when performing echocardiograms.… more - 📈EchoLab entered the top 10Top Paid · Medical · FR
- 📦EchoLab: first update in 229 days
- ✏️EchoLab: needs a newer iOSiOS 18.0 → iOS 18.6
- 📦EchoLab updated to version 14.0EchoLab v14.0:
• Analysis of prosthetic aortic, mitral, and pulmonic valves updated using the 2023 guidelines from the American Society of Echocardiography, the Society for Cardiovascular Magnetic Resonance, and the Society of Cardiovascular Computed Tomography.
• Option to designate surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) added to Quick Entry (aortic stenosis), Aortic Valve Area (VTI), and Aortic Valve Area (velocity) views.
• Quick Entry (pulmonic stenosis) added as a new view for assessment of native and prosthetic pulmonic valves, with the option to designate a bioprosthetic pulmonic valve or a pulmonic valve homograft.
• Updates for compatibility with iOS 27.
EchoLab is optimized for Dark Mode, ideal for use in the dimmed lighting of a typical echocardiography reading room.
Remember that designating Quick Entry views as favorites permits easy access to the most frequently used echocardiographic measurements under the Favorites tab. Designating the Demographics and Clinical Conditions view as a favorite is a great way to direct the Analytic Engine from a central point.
Remember also to check out the bundled Apple Watch app for EchoLab, providing a ready reference when performing echocardiograms.… more - 📈EchoLab charting in a new countryJapan
- 📈EchoLab entered the top 100Top Paid · Medical · US
- 📈EchoLab charting in a new countryUnited States
- 📈EchoLab entered the top 10Top Paid · Medical · KR
- 📈EchoLab entered the top 100Top Grossing · Medical · KR
- 📈EchoLab charting in a new countrySouth Korea
- 📈EchoLab charting in a new country in 3 chartsGermany · India · Russia
- 🆕EchoLab first spotted by AppInsider#89 in Top Paid · Medical · Brazil
- 📦EchoLab version 13.1EchoLab v13.1:
• Minor revision of the Analytic Engine for improved evaluation of left ventricular diastolic function using the 2025 guidelines from the American Society of Echocardiography (ASE).
• Aortic valve area from planimetry added to Quick Entry (aortic stenosis) view.
• Mitral valve area from planimetry added to Quick Entry (mitral stenosis) view.
EchoLab v13.0:
A significant update with a focus on left ventricular diastolic evaluation:
• Analytic engine and Quick Entry (diastology) view extensively revised for evaluation of left ventricular diastolic function using the 2025 guidelines from the American Society of Echocardiography (ASE), with separate analyses for “special populations” (atrial fibrillation, heart transplant, left ventricular assist device (LVAD), mitral annular calcification (MAC), and noncardiac pulmonary hypertension).
• Diastolic evaluation of hypertrophic cardiomyopathy revised to use the 2022 multimodality imaging guidelines from the ASE, American Society of Nuclear Cardiology, Society for Cardiovascular Magnetic Resonance, and Society of Cardiovascular Computed Tomography.
• Diastolic stress echocardiography updated to use the 2025 ASE diastolic evaluation guidelines.
• Normal values adjusted for left atrial reservoir strain, left ventricular global longitudinal strain, and right ventricular free wall strain to conform to the 2025 guidelines from the ASE and the European Association of Cardiovascular Imaging.
• Demographics and Clinical Conditions view updated to include special populations for diastolic evaluation.
EchoLab is optimized for Dark Mode, ideal for use in the dimmed lighting of a typical echocardiography reading room.
Remember that designating Quick Entry views as favorites permits easy access to the most frequently used echocardiographic measurements under the Favorites tab.
Remember also to check out the bundled Apple Watch app for EchoLab, providing a ready reference when performing echocardiograms.… more - 🆕EchoLab released on the App Store
Collected from the stores by AppInsider since we first spotted the app. Dates are when we saw each change.
EchoLab at a glance
AI summary written from our chart and store data, 2026-09-30. It can be wrong: check the numbers above.
EchoLab is a paid medical utility app for cardiologists and echocardiography technicians that provides quantitative cardiac ultrasound calculations, ASE/EACVI guideline integration, and an Apple Watch companion. The app holds top-100 positions in the Medical Paid charts across diverse markets including South Korea, Italy, Brazil, India, and Russia, indicating steady global niche demand despite having no user ratings on the current store listing.
Similar apps: CardioCalc, EchoReference, UpToDate
EchoLab on the App Store
App details
App privacy Measured
EchoLab declares it collects no data at all — the rarest and most private label on the App Store.
As declared by the developer on the App Store — Apple requires every app to publish this label. We track changes over time.
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| MedicalPaid | #81 | |
| MedicalPaid | #67 | |
| MedicalPaid | #139 | |
| MedicalPaid | #94 | |
| MedicalPaid | #131 | |
| MedicalPaid | #200 |
Apps near EchoLab on the chart
Medical Paid, around #81.
Ratings
App Store, worldwide.
Review momentum
ⓘ How we measure thisReview momentum (0-100) blends how fast the app collects ratings compared with other apps in its category (60%), whether that pace is speeding up (25%) and what recent raters give it (15%; recent stars well below lifetime pull it down). Ratings counts are read daily. A jump usually means a launch, a feature, ads or a new review prompt.
What users say about EchoLab
From recent reviews.
About EchoLab
Unique to EchoLab among echocardiography applications is the powerful Analytic Engine, which synthesizes results from multiple calculations into a cohesive overview with a comprehensive summary, with integration of ASE/EACVI guidelines. The included companion app for the Apple Watch provides a ready reference when performing or interpreting echocardiograms.
Available with each calculation is a graphical display of the corresponding mathematical equation, along with tips for using the calculation and medical literature references with integrated hyperlinks.
Calculations and analyses include:
• Aortic effective regurgitant orifice area
• Aortic energy loss index
• Aortic flow acceleration time with ratio to left ventricular ejection time
• Aortic prosthetic paravalvular regurgitant extent
• Aortic regurgitant fraction
• Aortic regurgitant jet width, jet area, pressure half-time, and vena contracta
• Aortic regurgitation index (for TAVR, from invasive pressure measurements)
• Aortic root assessment
• Aortic transvalvular flow rate
• Aortic valve area (from velocity and velocity-time integrals, including dobutamine stress with projected aortic valve area)
• Aortic valve resistance
• Aortic valvulo-arterial impedance (Zva)
• Biventricular coupling index
• Body mass index
• Body surface area
• Cardiac output and ejection fraction (3D, area-length, Doppler, Dumesnil, Teichholz, simplified Quinones, and Simpson's methods)
• Diastolic evaluation (using 2025 ASE guidelines for analysis)
• Diastolic stress echocardiography
• echocardiographic Pulmonary to Left Atrial Ratio (ePLAR)
• Exercise stress echocardiography
• Hemodynamic summary
• Left atrial appendage emptying velocity
• Left atrial pressure
• Left atrial expansion index, function index, and reservoir strain
• Left and right atrial volume and index
• Left ventricular diastolic diameter index
• Left ventricular dP/dt
• Left ventricular fractional shortening
• Left ventricular GLS
• Left ventricular mass, mass index, and relative wall thickness
• Left ventricular myocardial performance index
• Left ventricular stroke work loss
• Left ventricular wall motion score index
• Maximum predicted heart rate (for dobutamine and exercise stress)
• Maximum rate-pressure product (for exercise stress)
• Mean arterial pressure
• Mitral effective orifice area (PISA and stroke volume methods)
• Mitral regurgitant fraction (PISA and stroke volume methods)
• Mitral regurgitant vena contracta
• Mitral valve area (continuity, PISA, and pressure half-
Latest updates
Store changes
What EchoLab changed on its store page: name, icon, screenshots, price, size, languages, requirements.