Radiator Calculator Pro
Not in any tracked top chart right now.
Updated 19 Oct 2026 · rankings refresh through the day
DeveloperDigitalKind Ltd
CategoryUtilities
PriceFree
Released
Rating★ 2.3 (3)
Version1.5
Age rating4+
First seen by us
12 Oct 2026
Rating
2.3 ★
3 ratings
Measured
Radiator Calculator Pro on the App Store
App details
App ID
6743349772
Publisher
DigitalKind Ltd
On the store since
Mar 2025
1 year on the store
Minimum OS
iOS 26.0+
iPhone 11 and later
Devices
iPhone · iPad
Universal purchase
Content rating
4+
Languages
1
EN
Size
16 MB
Also listed in
Reference
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| Not charting right now. | ||
Ratings
App Store, worldwide.
Rating
2.3 ★
3 ratings
Measured
Ratings
3
Measured
About Radiator Calculator Pro
Room-by-room radiator sizing. Watts and BTU/h output for any room, factoring volume, glazing, external walls, roof and floor exposure, and insulation standard.
Calculation
Heat output per room with adjustments for:
• Room type (8 presets: bedroom, living room, bathroom, kitchen, hallway, office, conservatory, garage)
• Internal volume
• Window-to-floor ratio
• Number of external walls (0–4)
• What's above (loft, pitched roof, flat roof, heated space)
• What's below (garage, unheated cellar, uninsulated floor, heated floor)
• Insulation level: poor (older single-glazed) → average (modern build) → good → excellent (new-build, triple-glazed)
• Mean water temperature - ΔT30, ΔT35, ΔT40, ΔT50, ΔT60
ΔT correction uses the standard panel-radiator exponent (n = 1.30) per EN 442 testing convention. A 5% safety margin is applied to avoid undersizing.
Heat-pump systems
Select ΔT35 or ΔT30 to spec radiators for low-temperature systems. Output is rescaled — a 1000W ΔT50-rated radiator delivers ~630W at ΔT35 — so you size to actual delivered heat, not nameplate.
Output
• Watts and BTU/h side-by-side
• Metric or imperial dimensions
• Whole-home heat-loss total
• Share or export room specs as text
For plumbers, heating engineers, and heat-pump installers sizing radiator schedules, and homeowners or landlords running their own jobs.
Calculation
Heat output per room with adjustments for:
• Room type (8 presets: bedroom, living room, bathroom, kitchen, hallway, office, conservatory, garage)
• Internal volume
• Window-to-floor ratio
• Number of external walls (0–4)
• What's above (loft, pitched roof, flat roof, heated space)
• What's below (garage, unheated cellar, uninsulated floor, heated floor)
• Insulation level: poor (older single-glazed) → average (modern build) → good → excellent (new-build, triple-glazed)
• Mean water temperature - ΔT30, ΔT35, ΔT40, ΔT50, ΔT60
ΔT correction uses the standard panel-radiator exponent (n = 1.30) per EN 442 testing convention. A 5% safety margin is applied to avoid undersizing.
Heat-pump systems
Select ΔT35 or ΔT30 to spec radiators for low-temperature systems. Output is rescaled — a 1000W ΔT50-rated radiator delivers ~630W at ΔT35 — so you size to actual delivered heat, not nameplate.
Output
• Watts and BTU/h side-by-side
• Metric or imperial dimensions
• Whole-home heat-loss total
• Share or export room specs as text
For plumbers, heating engineers, and heat-pump installers sizing radiator schedules, and homeowners or landlords running their own jobs.
Latest updates
1.5
Thank you for using Radiator Calculator PRO. We’re always improving the app with performance enhancements, bug fixes, and tweaks to make the experience even better for you.