FemoroAcetabularImpingementApp
Not in any tracked top chart right now.
Updated 22 Oct 2026 · rankings refresh through the day
DeveloperORTHOPRACTIS.COM SINGLE MEMBER P.C.
CategoryMedical
Price39.90 BRL
Released
Rating★ 0.0 (0)
Version6.6
Age rating4+
First seen by us
29 Sep 2026
Rating
0.0 ★
0 ratings
Measured
FemoroAcetabularImpingementApp on the App Store
App details
App ID
1450712802
Publisher
ORTHOPRACTIS.COM SINGLE MEMBER P.C.
On the store since
Jan 2019
7 years on the store
Minimum OS
iOS 17.0+
iPhone XS and later
Devices
iPhone · iPad
Universal purchase
Content rating
4+
Languages
1
EN
Size
5 MB
Also listed in
Utilities
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| Not charting right now. | ||
Ratings
App Store, worldwide.
Rating
0.0 ★
0 ratings
Measured
Ratings
0
Measured
About FemoroAcetabularImpingementApp
Femoroacetabular impingement (FAI) is a recognized cause of hip pain in the young adult and is postulated to be a major cause of early osteoarthritis. Femoroacetabular impingement is a mismatch between the shape of the head–neck junction and the acetabulum. Hump malformation of the femoral head-neck junction (Cam) or femoral head acetabular over-coverage (pincer) leads to a damage to the articular cartilage and arthritis. The best radiological means of measuring FAI is CT scan or MRI, however, due to substantive radiation dose in CT and high cost in MRI, there are not routinely used in clinical practice for examinations. Femoral head/neck asphericity is best detected with the Dunn-projection-view in 45°, projection that is not always available. FAI is detectable also to an acceptable and conclusive level on standardised common AP pelvic radiographs.
The app is medical software aimed for orthopaedic surgeons, providing tools that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
Offers a very convenient way to determine the most accurate possibly lines in order to measure the angles. By the aid of a circular transparent template, the points of interest are marked accurately. The circular template help to detect and mark easily, the alpha point - where the radius of the curvature of the femoral head first exits the circle of best fit corresponding to a circular head - real turning point of asphericity of femoral head
The drawn lines between points, allows app to estimate in radiographs, Center-Edge Angle (CE), α - angle (aA) and the anterior femoral offset ratio (AfOR). The measured values are compared with values from normal reference database. In case the measured angles are beyond the normal range, the hip is categorized as normal, dysplastic, borderline dysplastic hip and the type of femoroacetabular impingement (FAI) deformity namely cam type, pincer type or mixed is printed over the screen accordingly. Measures by the app are not affected by the X-ray projection.
-Save the planned images, for later review or consultation.
Disclaimer.
Regarding its plausibility app offers no diagnosis or treatment. App provide an early indication that further evaluation may be warranted by Speciality Doctor. Explicitly is announced that the apps are not for diagnosis. Clinical judgment and experience are required to properly use the software. App alone do not replace an M.D. or specialist. All information received from the App output must be reviewed before any attempted treatment. The software is not for primary image interpretation. Any influence to the operators in making decisions remains user own responsibility and experience. App does not dispense medical advice. Patient should seek a doctor’s advice in addition using the app and /or before making any medical decisions for themself. Never substitute or replace doctors advice or change treatment modalities based on any measured outcome. App ind
The app is medical software aimed for orthopaedic surgeons, providing tools that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
Offers a very convenient way to determine the most accurate possibly lines in order to measure the angles. By the aid of a circular transparent template, the points of interest are marked accurately. The circular template help to detect and mark easily, the alpha point - where the radius of the curvature of the femoral head first exits the circle of best fit corresponding to a circular head - real turning point of asphericity of femoral head
The drawn lines between points, allows app to estimate in radiographs, Center-Edge Angle (CE), α - angle (aA) and the anterior femoral offset ratio (AfOR). The measured values are compared with values from normal reference database. In case the measured angles are beyond the normal range, the hip is categorized as normal, dysplastic, borderline dysplastic hip and the type of femoroacetabular impingement (FAI) deformity namely cam type, pincer type or mixed is printed over the screen accordingly. Measures by the app are not affected by the X-ray projection.
-Save the planned images, for later review or consultation.
Disclaimer.
Regarding its plausibility app offers no diagnosis or treatment. App provide an early indication that further evaluation may be warranted by Speciality Doctor. Explicitly is announced that the apps are not for diagnosis. Clinical judgment and experience are required to properly use the software. App alone do not replace an M.D. or specialist. All information received from the App output must be reviewed before any attempted treatment. The software is not for primary image interpretation. Any influence to the operators in making decisions remains user own responsibility and experience. App does not dispense medical advice. Patient should seek a doctor’s advice in addition using the app and /or before making any medical decisions for themself. Never substitute or replace doctors advice or change treatment modalities based on any measured outcome. App ind
Latest updates
6.6
What’s New in Version 6.6
This update focuses on improving usability, guidance, and workflow while preserving the validated FMI measurement methodology.
New Features
* Added interactive educational guidance for every anatomical landmark.
* New animated point-selection tutorials to assist with accurate landmark placement.
* Completely redesigned transparent floating interface for improved radiograph visibility.
* Floating anatomical guidance describing the next landmark to be selected.
* Compact liquid-style expandable and scrollable menus.
* One-tap hide/show controls for all floating interface panels.
* Improved image loading with better handling of large radiographs.
* Improved pan and zoom interaction.
* More stable concentric selection pointer.
* Double-tap now consistently registers the centre of the targeting reticle for improved accuracy.
* Improved point editing and correction workflow.
* Improved measurement navigation between anatomical landmarks.
* Better support for high-resolution radiographic images.
* Updated launch consent workflow presented at every application launch.
* Updated Privacy Policy and Terms of Use.
* Improved Help section and in-app guidance.
* General user interface refinements.
* Performance and stability improvements.
* Swift 6.1 compatibility improvements.
* Improved compatibility with the latest iOS, iPadOS and visionOS releases.
* Numerous bug fixes and internal optimizations.
Measurement
* Preserves the original FMI methodology.
* Preserves CE Angle calculations.
* Preserves Alpha Angle calculations.
* Preserves AfOR calculations.
* Preserves existing diagnostic thresholds and workflow.
Stability
* Improved overall reliability.
* Reduced unexpected point movement during selection.
* Improved rendering performance.
* Better memory management when loading large images.
* General bug fixes and code modernization.