SpinopelvicBalanceApp
SpinopelvicBalanceApp is #20 in Medical Paid in China and charting in 1 of 30 countries we track.
Updated 25 Oct 2026 · rankings refresh through the day
DeveloperORTHOPRACTIS.COM SINGLE MEMBER P.C.
CategoryMedical
Price999.00 INR
Released
Rating★ 0.0 (0)
Version4.5
Age rating17+
First seen by us
5 Oct 2026
Rating
0.0 ★
0 ratings
Measured
Best rank now
#20
Measured
SpinopelvicBalanceApp on the App Store
App details
App ID
1360640710
Publisher
ORTHOPRACTIS.COM SINGLE MEMBER P.C.
On the store since
Mar 2018
8 years on the store
Minimum OS
iOS 15.4+
iPhone 6s and later
Devices
iPhone · iPad
Universal purchase
Content rating
17+
1 content note below
Languages
1
EN
Size
1 MB
Also listed in
Utilities
Content notesFrequent/Intense Medical/Treatment Information
Where SpinopelvicBalanceApp's downloads come from Modelled
Last 30 days: organic search, browsing the store, features and paid ads.
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| MedicalPaid | #20 |
Apps near SpinopelvicBalanceApp on the chart
Medical Paid, around #20.
Ratings
App Store, worldwide.
Rating
0.0 ★
0 ratings
Measured
Ratings
0
Measured
About SpinopelvicBalanceApp
The assessment of the parameters involved in spinopelvic jucture are of paramount importance for spine and joint replacement surgeon. The dynamic interplay between flexibility and balance around the axis of gravity determine the type and the amount of influence in spine and hips. Radiographic parameters to evaluate objectively the spinopelvic sagittal balance are Pelvic incidence (PI), Sacral slope (SS), Pelvic Tilt (PT), Lumbar lordosis (LL). Drawings in patients X-rays and precise measurements are important in order to quantify the magnitude of spinal deformities, to monitor the success or failure of treatment and thus optimise the management of patients according to the severity of the imbalance or even to identify patient at risk of degenerative spondylolisthesis or disk herniation.
The Spinopelvic Balance App is medical software aimed for orthopaedic surgeons, providing tools that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking few points at the image of X-ray, the App calculates and offers a very convenient way to determine the most accurate possibly way at once, Pelvic incidence (PI), Sacral slope (SS), Pelvic Tilt (PT), Lumbar lordosis (LL), thoracic kyphosis, PI–LL Pelvic incidence Angle (PI) minus Lumbar lordosis Angle (LL) PI–LL, theoretical normal pelvic tilt (tPT),theoretical normal L1-S1 lumbar lordosis (tL1S1), Pelvic Radius Angle (PRA). According to measured parameters the app categorises the severity of the imbalance of spine, in different stages: optimal or non optimal.
-Save the planned images, for later review or consultation.The measured values are compared by normal reference databases and also data are exported as txt file, ready to print or to input as cells to excel for research.
-The app allows choosing between simple and extended method according to everyday preference and also by choosing points in vertebra body in a independent manner from order.
-The app can be used to measure L5 Incidence (L5I) Angle or L4 respectively.
-The app offers theoretical value estimation this is particularly useful because a sensible difference between theoretical value and measured value reveals a compensation phenomenon if the pelvis tilt (PT) is higher than its theoretical value, then it is due to pelvis retroversion, which is a compensation phenomenon. Knowing the theoretical value of Pelvis Tilt (PT) provided it is easy to understand that a sensible difference between theoretical value and measured value is a compensation phenomenon.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! Spinopelvic Balance App indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy everyday practice, the examiner have to draw lines in X-rays or in clinical settings, this it is ti
The Spinopelvic Balance App is medical software aimed for orthopaedic surgeons, providing tools that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking few points at the image of X-ray, the App calculates and offers a very convenient way to determine the most accurate possibly way at once, Pelvic incidence (PI), Sacral slope (SS), Pelvic Tilt (PT), Lumbar lordosis (LL), thoracic kyphosis, PI–LL Pelvic incidence Angle (PI) minus Lumbar lordosis Angle (LL) PI–LL, theoretical normal pelvic tilt (tPT),theoretical normal L1-S1 lumbar lordosis (tL1S1), Pelvic Radius Angle (PRA). According to measured parameters the app categorises the severity of the imbalance of spine, in different stages: optimal or non optimal.
-Save the planned images, for later review or consultation.The measured values are compared by normal reference databases and also data are exported as txt file, ready to print or to input as cells to excel for research.
-The app allows choosing between simple and extended method according to everyday preference and also by choosing points in vertebra body in a independent manner from order.
-The app can be used to measure L5 Incidence (L5I) Angle or L4 respectively.
-The app offers theoretical value estimation this is particularly useful because a sensible difference between theoretical value and measured value reveals a compensation phenomenon if the pelvis tilt (PT) is higher than its theoretical value, then it is due to pelvis retroversion, which is a compensation phenomenon. Knowing the theoretical value of Pelvis Tilt (PT) provided it is easy to understand that a sensible difference between theoretical value and measured value is a compensation phenomenon.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! Spinopelvic Balance App indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy everyday practice, the examiner have to draw lines in X-rays or in clinical settings, this it is ti
Latest updates
4.5
bugs fixed and updated