Odrid HMI Downloads & RevenueOdrid HMI · App Store
Odrid HMI is #22 in Productivity Paid in Sweden and charting in 1 of 30 countries we track.
Updated 11 Nov 2026 · rankings refresh through the day
Full timeline · 8 events
- 📈Odrid HMI entered the top 10Top Paid · Productivity · MX
- 📈Odrid HMI entered the top 10Top Paid · Productivity · SE
- 📈Odrid HMI charting in a new country in 2 chartsMexico · Sweden
- 📈Odrid HMI entered the top 100Top Paid · Productivity · DE
- 📈Odrid HMI charting in a new countryGermany
- 🆕Odrid HMI first spotted by AppInsider#34 in Top Paid · Productivity · Canada
- 📦Odrid HMI version 1.7.13Bug fix for an issue where text entered in the comment field in the GUI objects after a directive or a script could cause the app to stop responding.
Bug fix for the firstScan script property in the Button object not working.… more - 🆕Odrid HMI released on the App Store
Collected from the stores by AppInsider since we first spotted the app. Dates are when we saw each change.
Odrid HMI on the App Store
App details
Odrid HMI downloads
Worldwide, per day, and installs to date. The band is open; the exact number is free with an account.
How this is calculated
Where Odrid HMI's downloads come from Modelled
Last 30 days: organic search, browsing the store, features and paid ads.
Active users
All platforms, worldwide. Free with an account.
How this is calculated
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| ProductivityPaid | #22 | |
| All AppsPaid | #190 |
Apps near Odrid HMI on the chart
Productivity Paid, around #22.
Ratings
App Store, worldwide.
Review momentum
ⓘ How we measure thisReview momentum (0-100) blends how fast the app collects ratings compared with other apps in its category (60%), whether that pace is speeding up (25%) and what recent raters give it (15%; recent stars well below lifetime pull it down). Ratings counts are read daily. A jump usually means a launch, a feature, ads or a new review prompt.
What users say about Odrid HMI
From recent reviews.
About Odrid HMI
Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).
Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between pages using swipe gestures or buttons.
Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.
Advantages:
Excellent technical support.
Free updates.
Graphic HMIs with multi touch function can be created in minutes.
Free-of-charge development tool with test run feature.
Virtually unlimited number of pages, objects and variables.
Does not require any third-party services.
Genuine native app.
Features:
Parameters for communication such as IP address, port number, protocol, etc. can be specified per page.
Automatic polling of all variables displayed in the current page, no need for separate tag list.
Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
Prioritized event-driven transfer to the controller.
Pages are edited in the measurement unit dp (Density Independent Pixels).
Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
Detailed diagnostics of connection and communication.
Variable areas for system variables, local variables and constants.
Possibility of automatic return to the start page after some time of inactivity.
Selectable order for high and low words of 32-bit variables in the Modbus protocol.
Poll interval can be set do save data traffic or battery.
Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets.
Ability to test run pages in the development tool.
LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
Background color for pages can be selected.
Modbus Device ID can be changed with GUI objects during operation.
Image buttons.
Password fields.
Floating point and hexadecimal number formatting.
Timestamp for page files.
Hyperlinks.
Document information in page files.
Implemented protocols in the current version:
Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.
Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).
Modbus RTU: Class 0 and 1.
Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.
(Default value for highest