CupAnteversionInclinationApp Downloads & RevenueCupAnteversionInclinationApp · App Store
Not in any tracked top chart right now.
Updated 7 Nov 2026 · rankings refresh through the day
DeveloperORTHOPRACTIS.COM SINGLE MEMBER P.C.
CategoryMedical
Price4.99 GBP
Released
Rating★ 0.0 (0)
Version5.0
Age rating17+
First seen by us
4 Nov 2026
CupAnteversionInclinationApp update history & changes
Last change · 3 events since 13 Jan 2019Full timeline ↓Full timeline · 3 events
- 🆕CupAnteversionInclinationApp first spotted by AppInsider#20 in Top Paid · Medical · United Kingdom
- 📦CupAnteversionInclinationApp version 5.0minor bugs fixed
- 🆕CupAnteversionInclinationApp released on the App Store
Collected from the stores by AppInsider since we first spotted the app. Dates are when we saw each change.
Rating
0.0 ★
0 ratings
Measured
CupAnteversionInclinationApp on the App Store
App details
App ID
1448919739
Publisher
ORTHOPRACTIS.COM SINGLE MEMBER P.C.
On the store since
Jan 2019
7 years on the store
Minimum OS
iOS 13.2+
iPhone 6s and later
Devices
iPhone · iPad
Universal purchase
Content rating
17+
1 content note below
Languages
1
EN
Size
1 MB
Also listed in
Productivity
Content notesFrequent/Intense Medical/Treatment Information
Where it ranks now
Every top chart it appears in across 30 countries.
| Country | Charts | Rank |
|---|---|---|
| Not charting right now. | ||
Ratings
App Store, worldwide.
Rating
0.0 ★
0 ratings
Measured
Ratings
0
Measured
About CupAnteversionInclinationApp
In Total hip Arthroplasty the orientation, namely anteversion and inclination of the new acetabular component -cup- influences wear, range of movement (ROM), and the likelihood of dislocation after total hip replacement (THR). Evaluating objectively of the cup anteversion, and inclination in hip arthroplasty replacement surgery is of paramount importance. Radiographs are the most important diagnostic means in the follow-up for evaluation of a total hip arthroplasty. Measuring anteversion and inclination in everyday clinical setting is a cumbersome work for a medical doctor. Computation requires a calculator, which requires an additional effort during practice and slows down workflow.
The App is medical software aimed for orthopaedic surgeons, providing a tool that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated. The app is based on Widmer’s method which is the proven that is the most accurate compared to others.
-Pelvic tilt expressed by the angle APP is incorporated in measurements and can be adjusted manually according to surgeons preference.
-Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle).
- RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).
-The data are printed over to screen so each case can easily assessed.
-For more accurate results the source of central ray of the x-ray should be at position at 1150mm away from x ray table .
-Save the planned images, for later review or consultation.
The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! The App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time. Please see tutorial videos at the developer’s web site www.orthopractis.com
Reference
1. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014 May;96-B(5):597-603.
2. Bachhal V, Jindal N, Saini G, Sament R, Kumar V, Chouhan D, Dhillon M. A new method of measuring acetabul
The App is medical software aimed for orthopaedic surgeons, providing a tool that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated. The app is based on Widmer’s method which is the proven that is the most accurate compared to others.
-Pelvic tilt expressed by the angle APP is incorporated in measurements and can be adjusted manually according to surgeons preference.
-Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle).
- RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).
-The data are printed over to screen so each case can easily assessed.
-For more accurate results the source of central ray of the x-ray should be at position at 1150mm away from x ray table .
-Save the planned images, for later review or consultation.
The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! The App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time. Please see tutorial videos at the developer’s web site www.orthopractis.com
Reference
1. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014 May;96-B(5):597-603.
2. Bachhal V, Jindal N, Saini G, Sament R, Kumar V, Chouhan D, Dhillon M. A new method of measuring acetabul
Latest updates
5.0
minor bugs fixed